The information in this document is subject to change without prior notice in order to improve reliability, design and function and does not represent a commitment on the part of the manufacturer.
In no event will the manufacturer be liable for direct, indirect, special, incidental, or consequential damages arising out of the use or inability to use the product or documentation, even if advised of the possibility of such damages.
This document contains proprietary information protected by copyright. All rights are reserved. No part of this manual may be reproduced by any mechanical, electronic, or other means in any form without prior written permission of the manufacturer.
Trademarks
ACLD-9185 is registered trademarks of ADLink Technology Inc. IBM PC is a registered trademark of International Business Machines Corporation. Intel is a
registered trademark of Intel Corporation. Other product names mentioned herein are used for identification purposes only and may be trademarks and/or registered
trademarks of their respective companies.
Contents
This manual is designed to help you use the ACLD-9185. The manual describes how to modify various settings on the ACLD-9185 card to meet your requirements. It is divided into five chapters:
The ACLD-9185 is an inexpansive 16-channel SPDT form C relay output board for ISA bus computer in industrial applications. It is fully hardware and software compatible with Advantech's PCLD-785.
The ACLD-9185 provides 16 electromechanical SPDT relay which can be used by any ACL series digital output board with D/O channels on 20-pin flat ribbon connector. You can use 16 on-board relay to control power switches. Each relay is matched with one LED to reflect it's ON/OFF status.
Each relay consumes about 33 mA when energized. When all relays on the board are active , the board takes about 0.53 A
from the computer's 12V power bus. Normally the current driving capability of the 12V power source is not good enough . The
ACLD-9185 has a jumper switch allowing the user to connect an external +12V power source.
1.1 Features
The ACLD-9185 Relay Actuator and D/I Card provides the following advanced features:
| Output Channels | 16 |
| Relay Type | 16 SPDT ( Form C ) |
| Contact rating | 120V AC/DC , 1 A |
| Breakdown Voltage | 1000 V AC/DC min.. |
| Release time | 5 msec max. |
| Operate time | 5 msec max.. |
| Relay ON time | 3 msec typical |
| Relay OFF time | 3 msec typical |
| Total switching time | 10 msec typical |
| Insulation Resistance | 100 mega Ohms min. |
| Life Expectancy | > 5 million operations at full load |
| Power Consumption | +12V , 33 mA for each relay , total 0.264 A if all relay are energized +5V, less than 0.2A |
| Power supply | + 12V from the PC-Bus |
| Size | 203 mm X 132mm |
| Connectors | 20-pin flat cable |
This chapter describes how to install the ACLD-9185. At first, the contents in the package and unpacking information that
you should be careful are described. The jumpers setting for the ACLD-9185's base power source selection are also specified.
2.1 What You Have
In addition to this User's Manual, the package includes the following items:
If any of these items is missing or damaged, contact the dealer from whom you purchased the product. Save the shipping
materials and carton in case you want to ship or store the product in the future.
2.2 Unpacking
Your ACLD-9185 card contains sensitive electronic components that can be easily damaged by static electricity.
The card should be done on a grounded anti-static mat. The operator should be wearing an anti-static wristband, grounded at the same point as the anti-static mat.
Inspect the card module carton for obvious damage. Shipping and handling may cause damage to your module. Be sure there are no shipping and handing damages on the module before processing.
After opening the card module carton, exact the system module and place it only on a grounded anti-static surface component side up.
Again inspect the module for damage. Press down on all the socketed IC's to make sure that they are properly seated. Do this only with the module place on a firm flat surface.
Note : DO NOT APPLY POWER TO THE CARD IF IT HAS BEEN DAMAGED.
You are now ready to install your ACLD-9185.
2.3 ACLD-9185's Layout

Figure 2.1
2.3 Connector Pin Assignments
The relationship between connector pins driver IC's, relay connects, LED's, and resistor arrays on the ACLD-9185 is shown in the following table:
| CN1 PIN |
ULN2003 IN OUT |
RELAY | RELAY Contacts | LED | Resistor | Array||||
| 1 | U3 | 4 | 13 | K0 | COM0 | NC0 | NO0 | 0 | RP1 |
| 2 | U3 | 5 | 12 | K1 | COM1 | NC1 | NO1 | 1 | RP1 |
| 3 | U3 | 3 | 14 | K2 | COM2 | NC2 | NO2 | 2 | RP1 |
| 4 | U3 | 6 | 11 | K3 | COM3 | NC3 | NO3 | 3 | RP1 |
| 5 | U3 | 2 | 15 | K4 | COM4 | NC4 | NO4 | 4 | RP1 |
| 6 | U3 | 7 | 10 | K5 | COM5 | NC5 | NO5 | 5 | RP1 |
| 7 | U3 | 1 | 16 | K6 | COM6 | NC6 | NO6 | 6 | RP1 |
| 8 | U2 | 1 | 16 | K7 | COM7 | NC7 | NO7 | 7 | RP1 |
| 9 | U2 | 7 | 16 | K8 | COM8 | NC8 | NO8 | 8 | RP2 |
| 10 | U2 | 2 | 16 | K9 | COM9 | NC9 | NO9 | 9 | RP2 |
| 11 | U2 | 6 | 16 | K10 | COM10 | NC10 | NO10 | 10 | RP2 |
| 12 | U2 | 3 | 16 | K11 | COM11 | NC11 | NO11 | 11 | RP2 |
| 13 | U2 | 5 | 16 | K12 | COM12 | NC12 | NO12 | 12 | RP2 |
| 14 | U2 | 4 | 16 | K13 | COM13 | NC13 | NO13 | 13 | RP2 |
| 15 | U1 | 7 | 10 | K14 | COM14 | NC14 | NO14 | 14 | RP2 |
| 16 | U1 | 6 | 10 | K15 | COM15 | NC15 | NO15 | 15 | RP2 |
| 17 | Ground | ||||||||
| 18 | Ground | ||||||||
| 19 | +5 DC | ||||||||
| 20 | +12 DC | ||||||||
The ACLD-9185's power source can come from internal ( provided by PC bus) or external ( provided by external DC +12V). Both of internal and external source can provide +12V and +5V, respectively. The description of power source is specified as following table:
| Internal power | +12V +5V |
Provided by PC bus |
| External power | +12V +5V |
Provided by external DC source through connector CN2 |
The desired power source is selected by jumpers :
The ACLD-9185 contains 16 SPDT Form C relays, the connection of Form C realy is shown as the following diagram.
This relay has three contacts : NC ( Normal Close), NO ( Normal Open), and COM( Common). The CM post, located at the middle, can make contact either NO post or NC post. When the control bit is high (1), the COM post and NO post are contacted. If the control bit is low (0), the COM post and NC post make contact.
In normal power-up and reset, the relay is in low status.
2.7 Connection
The ACLD-9185 is digital output daughter board which comes equipped with ACL series multi-function data acquisition cards and digital I/O card. The connection configurations of ACL series cards and the ACLD-9185 are shown as below.
2.7.1. Multi-function Cards and ACLD-8195
![]() |
|
| PCI-9112, ACL-8316 ACL-812PG, ACL-8112 Series ACL-8111, ACL-8216 ACL-6126, ACL-8118 Series |
2.7.2. ACL Digital I/O Cards and ACLD-8195
![]() |
|
| ACL-7120, ACL-720 |
Seller warrants that equipment furnished will be free form defects in material and workmanship for a period of one year from the confirmed date of purchase of the original buyer and that upon written notice of any such defect, Seller will, at its option, repair or replace the defective item under the terms of this warranty, subject to the provisions and specific exclusions listed herein.
This warranty shall not apply to equipment that has been previously repaired or altered outside our plant in any way as to, in the judgment of the manufacturer, affect its reliability. Nor will it apply if the equipment has been used in a manner exceeding its specifications or if the serial number has been removed.
Seller does not assume any liability for consequential damages as a result from our products uses, and in any event our liability shall not exceed the original selling price of the equipment.
The equipment warranty shall constitute the sole and exclusive remedy of any Buyer of Seller? equipment and the sole and exclusive liability of the Seller, its successors or assigns, in connection with equipment purchased and in lieu of all other warranties expressed implied or statutory, including, but not limited to, any implied warranty of merchant ability or fitness and all other obligations or liabilities of seller, its successors or assigns.
The equipment must be returned postage-prepaid. Package it securely and insure it. You will be charged for parts and labor if you lack proof of date
of purchase, or if the warranty period is expired.


©1995 Circuit Specialists, Inc.