![]() FC-2015 150MHz |
![]() FC-2015U 150MHz |
![]() FC-2130 1.3GHz |
![]() FC-2130U 1.3GHz |
| - | FC-2015 | FC-2130 | FC-2015U | FC-2130U |
| Display | 8 Digit (0.56" Green LED display) over, Hz, MHz, HOLD, Gate Time, ns, ms, s | |||
| Frequency Measurement | ||||
| Range | 0.2Hz~150MHz | 0.2Hz~1.3GHz | 0.2Hz~150MHz | 0.2Hz~1.3GHz |
| Gate Time | 0.01S, 0.1S, 1S, 10S | |||
| Resolution | 100nHz ~ 10Hz | |||
| L.S.D. Displayed | 100nHz ~ 10Hz depending upon gate time and input signal at least 8 digit displayed in 10 second of gate time | |||
| Accuracy | ± Resolution ± Timebase error ± 1 count | |||
| - | FC-2015 | FC-2130 | FC-2015U | FC-2130U | |
| Input Characteristics | |||||
| Sensitivity | Input A | 25mVrms : 0.2Hz ~ 110MHz, 50mVrms : 100MHz ~ 150MHz | |||
| Input B | -- | 30mVrms : 50MHz~1.1GHz 60mVrms : 1.1GHz~1.3GHz |
25mVRMS : 0.2Hz~100MHz | -- | |
| Input C | -- | -- | -- | 30mVrms : 50MHz~1.0GHz 60mVrms : 1GHz~1.3GHz |
|
| Impedance | Input A | 1MW, <40pF | |||
| Input B | -- | 50W | 1MW, <40pF | ||
| Input C | -- | -- | -- | 50W | |
| Max Input Voltage | Input A | 250Vrms | 250Vrms | 250Vrms | |
| Input B | -- | 3Vrms | 250Vrms | ||
| Input C | -- | -- | -- | 3Vrms | |
| Attenuator | Input A | x1, x10 | |||
| Input B | -- | -- | x1, x10 | ||
| Slope | Input A, B | -- | -- | +, - switchable | |
| Input A | -- | -- | Preset or Variable | ||
| LP Filter | Input A | 100kHz, -3dB | 100kHz, -3dB | 100kHz, -3dB | |
| Input B | -- | -- | 100kHz, -3dB | ||
| - | FC-2015 | FC-2130 | FC-2015U | FC-2130U |
| Period Measurement (Input A -- B) | ||||
| Range | 6.7ns ~ 5s | |||
| L.S.D. Displayed | n, u, m, sec with decimal point | |||
| Time Interval Measurement (Input A -- B) | ||||
| Range | - | 0.5usec ~5sec (0.2Hz ~ 2MHz) | ||
| L.S.D. Displayed | - | 100ns | ||
| Resolution | - | ±LSD ±Trigger error | ||
| Accuracy | - | ±Resolution ±Time base error XT.1 | ||
| Ratio Measurement (Input A -- B) | ||||
| Range | - | Input A:10Hz ~ 10MHz, Input B: 10Hz ~ 10MHz | ||
| Resolution | - | ± (Freq A x N/Freq B) (n=1, 10, 100, 1000) | ||
| Accuracy | - | ±{Freq B + Freq (AxN)} ± (Freq B x trigger error/N) | ||
| Total Measurement (Input A) | ||||
| Range | DC ~ 10MHz | |||
| Count Capacity | 0 ~ 99999999 (max) | |||
| Time Base Characteristics | ||||
| Frequency | 10MHz (int/ext) TCO | |||
| Stability | 1PPM (±1 count) | |||
| Line Voltage Stability | Less than ±1PPM with ±10% line voltage variation | |||
| Max. Aging Rate | ± 5PPM/year | |||
| General | ||||
| Operating Temperature | 0 ~ 40°C (Accuracy specified at 25°C ±5°C) | |||
| Power Requirements | AC 100/120/220/240V ±10% (50Hz/60Hz) | |||
| Dimensions | 255(W) x 80(H) x 260(D)mm | |||
| Weight | Approx. 1.8kg | |||
| Accessories | Power cord, BNC cable, Fuse, Operator's manual | |||
| Cat No. | Product Description | Price |
| FC-2015 | 0.2Hz - 150MHz | $249.00 |
| FC-2015U | 0.2Hz - 150MHz with Time Interval & Ratio | $299.00 |
| FC-2130 | 0.2Hz - 1.3GHz | $289.00 |
| FC-2130U | 0.2Hz - 1.3GHz with Time Interval & Ratio | $349.00 |
Low-Frequency Function Generator

This function generator (a.k.a. audio oscillator) features switchable
output impedance, push-button selection of the 400Hz and 1KHz standard audio
test frequencies, and use of its display for measuring the frequency of
an external signal.
Features
Specifications
| Frequency Range | 10Hz~1MHz, in 5 decade steps variable control 10:1 |
| Frequency Indicator | 4 digit green LED display |
| Frequency Accuracy | ±1 digit (4 digit max) |
Sine Wave Characteristics |
|
| Output Voltages | 8Vrms or more |
| Frequency Response | 10Hz~1MHz ± 0.5dB, ref. freq. 1kHz |
| Distortion Factor | 50Hz~500kHz : 0.5% or less |
Square Wave Characteristics |
|
| Output Voltage | 10Vp-p or more (open circuit) |
| Rise and Fall Times | 200ns or less |
| Overshoot | 2% or less (at 1kHz, Max. output) |
| Duty Ratio | 50% ±5% (at 1kHz, Max. output) |
External Synchronization Characteristics |
|
| Input Impedance | Approx. 10kW |
| Max. Allowable Input | 10Vrms |
Output Characteristics |
|
| Impedance (changeable) | 600W or 50W ±5% |
| Attenuator | 0dB, -10dB, -20dB, -40dB (accuracy: ±1dB) |
| Variable | -60dB or more |
Frequency Characteristics (int/ext) |
|
| Display | 4 digit green LED display |
| Frequency Range | 10Hz~1MHz (0.5s, 1s) |
| Accuracy | Timebase error ±1 count |
| Max. Input Voltage | 150Vrms (at 1kHz) |
| Input Sensitivity | 130mVrms |
| Input Impedance | Approx. 1MW / / 25pF |
| CAT NO | DESCRIPTION |
PRICE |
| AO-3001C | Low-Frequency Function Generator |
$229.00 |
True RMS Digital Bench-Top Multimeter

ONLY
$199.00
The DM-441B is a 4 1/2 digit, 20,000 count bench top multimeter. This
true RMS meter has a basic accuracy of 0.05%. The DM-441B supports a full
range of functions including: frequency, resistance, voltage, current with
transistor check and added features like data hold, and continuity. The
DM-441B is overload protected to 600 volts in the resistance ranges.
Features
| Function | Range | Resolution |
| DC Voltage | 200 mV | 10 uV |
| 2 V | 100 uV | |
| 20 V | 1 mV | |
| 200 V | 10 mV | |
| 1000 V | 100 mV | |
| AC Voltage | 200 mV | 10 uV |
| 2 V | 100 uV | |
| 20 V | 1 mV | |
| 200 V | 10 mV | |
| 750 V | 100 mV | |
| DC Current | 2 mA | 0.1 uA |
| 20 mA | 1 uA | |
| 200 mA | 10 uA | |
| 2 A | 100 uV | |
| 10 A | 10 mA | |
| AC Current | 2 mA | 0.1 uA |
| 20 mA | 1 uA | |
| 200 mA | 10 uA | |
| 2 A | 100 uA | |
| 10 A | 10 uA | |
| Resistance | 200W | 10 mW |
| 2 KW | 0.1 W | |
| 20 KW | 1W | |
| 200 KW | 10 W | |
| 2 MW | 100 W | |
| 20 MW | 1 KW | |
| Frequency | 20 KHz | 1 Hz |
| 200 KHz | 10 Hz | |
| TR hfe | Base Current: 3.5uA, Vce: Approx. 4.5V | |
| Diode Continuity | Test Voltage: 4.5V approx., Maximum Test Current: 1mA |
|
| CAT NO | DESCRIPTION |
PRICE |
| DM-441B | True RMS Bench Top DMM |
$199.00 |
Function Generators


| Cat No. | Product Description | Price |
| FG-2002C | Function Generator w/Digital Display | $299.00 |
| FG8002 | Function Generator | $199.00 |
FaxBack: 1-800-662-5426 (602-834-1005 in Arizona)
Get All of the Facts About these Goldstar Products delivered to your Fax Machine in a Matter of Minutes.